Section 01
Ultrasonic Inspection Applications
- Internal discontinuities in laminate
- Composite delamination and disbond
- Bond-line inspection where appropriate
- Thickness evaluation where appropriate
- Corrosion thinning in metallic structure
- Pre- and post-repair verification
Section 02
Composite Ultrasonic Inspection
UT defines the true boundary of delamination and core damage, so composite repairs remove only what is necessary and leave sound material in place.
Section 03
Metallic Structure
On metallic structure, UT thickness readings help quantify material loss from corrosion or blending against allowable limits.
Section 04
Mobile UT Inspection
Jax Aerospace is based at Northeast Florida Regional Airport in St. Augustine. Mobile service is available throughout Florida and the Southeast depending on job scope, aircraft location, repair requirements, and equipment. Where a repair is better performed in a controlled environment, components can be brought to our facility.